The instrument is our company all scientific and technical personnel, according to the relevant provisions of national standard GB507-1986 and line standard DL/T846.7-2004, exert their own advantages, after many field tests and long-term unremitting efforts, carefully developed high accuracy, full digital industrial instrument. In order to meet the needs of different users, the series of instruments can be divided into single cup, three cups and multiple cups. The instrument is easy to operate and beautiful in shape. Due to the use of automatic digital microcomputer control, so the measurement of high precision, strong anti-interference ability, safe and reliable.
二、Technical indicators
1. Capacity of booster 1.5kVA
2. Boost speed of 0.5kV/s-5.0kV/s (increasing every 0.5) 10 grades optional
Difference of 0.2 kV/s by mistake
3. Output voltage 0 ~ 80 kV (optional)
4. Voltage accuracy (2% reading +2 words)
5. Power distortion rate < 1%
6. Electrode clearance standard 2.5mm
7. Test times: 6 times (1-10 times optional)
8. Resting time 900S(0-5900s optional)
9. Interval rest time 300S(0-5900s optional)
10. Stirring time 15S (0-250s optional)
11. Display mode Large LCD Chinese characters display
12. Communication port 232 communication port is standard.
13. Overall dimension length 430 mm; 350 mm wide; 370 mm high